FLIR A310 Thailand Infrared Camera Specifications
Safety: the Infrared eye that never sleeps
The FLIR A310 camera offers an affordable and accurate temperature measurement solution for anyone who needs to solve problems that need built in "smartness" such as analysis, alarm functionality and autonomous communication using standard protocols. The FLIR A310 camera also has all the necessary features and functions to build distributed single- or multi-camera solutions utilizing standard Ethernet hardware and software protocols.
The FLIR A310 camera also has built in support to connect to industrial control equipment such as PLCs, and allows for sharing of analysis and alarm results and simple control using the Ethernet/IP and Modbus TCP field bus protocol.
Imaging and optical data |
|
Field of view (FOV) | 25° x 18.8° |
Minimum focus distance | 0.4m |
Focal Length | 18mm |
Spatial resolution | 1.36mrad |
Lens identification | Automation |
F-number | 1.3 |
Thermal sensitivity/ NETD | <0.05°C @ + 30°C/ 50mK |
Image frequency | 30Hz |
Focus | Automatic or manual (built in motor) |
Zoom | 1-8x continuous, digital, interpolating zooming on images |
Detector data |
|
Detector type | Focal Plane Array (FPA), uncooled microbolometer |
Spectral range | 7.5-13μm |
IR resolution | 320 x 240pixels |
Detector pitch | 25μm |
Detector time constant | Typical 12ms |
Measurement |
|
Object temperature range | -20°C to + 120°C 0 to +350°C |
Accuracy | ±2°C or ±2% of reading |
Measurement analysis |
|
Spotmeter | 10 |
Area | 10 boxes with max./min./average/position |
Isotherm | 1 with above/ below/ interval |
Measurement Option | Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP) |
Difference temperature | Delta temperature between measurement functions or reference temperature |
Atmosphere transmission | Automatic, based on inputs for distance, atmospheric temperature and relative humidity |
Optics transmission correction |
Automatic, based on signals from internal sensors |
Emissivity correction | Variable from 0.01 to 1.0 |
Reflected apparent temperature correction |
Automatic, based on input of reflected temperature |
External optics/ windows correction |
Automatic, based on input of optics/ window transmission and temperature |
Measurement corrections | Global object parameters |
Alarm |
|
Alarm functions | 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer Digital Out, Log, store image, file sending (ftp) |
Alarm output | email (SMTP), notification |
Set-up |
|
Color palettes | Color palettes (BW, BW inv, Iron, Rain) |
Set-up commands | Date/ time, Temperature°C |
Storage of images |
|
Image storage type | Built-in memory for image storage |
File format | Standard JPEG, 16-bit measurement data included |
Ethernet |
|
Ethernet | Control and image |
Ethernet, type | 100Mbps |
Ethernet, standard | IEEE 802.3 |
Ethernet, connector type | RJ-45 |
Ethernet, communication | TCP/IP socket-based FLIR proprietary |
Ethernet, video streaming | MPEG-4, ISO.IEC 14496-1 MPEG-4 ASP@L5 |
Ethernet, image streaming | 16-bit 320 x 240 pixels @ 3 Hz |
Ethernet, power | Power over Ethernet, PoE Ieee 802.3af class 0 |
Ethernet, protocols | TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP |
Digital input/output |
|
Digital input, purpose | Image tag (start/ stop/ general), Input ext. device (programmatically read) |
Digital input | 2 opto-isolated, 10-30 VDC |
Digital ouput, purpose | Output to ext. device (programmatically set) |
Digital ouput | 2 opto-isolated, 10-30 VDC, max 100mA |
Digital I/O, isolation voltage | 500VRMS |
Digital I/O, supply voltage | 12/24 VDC, max 200 mA |
Digital I/O, connector voltage | 6-pole jackable screw terminal |
Composite video |
|
Video out | Composite video output, PAL and NTSC compatible |
Video, standard | CVBS (ITU-R-BT.470 PAL/ SMPTE 170M NTSC) |
Video, connector type | Standard BNC connector |
Power system |
|
External power operation | 12/24 VDC, 24W absolute max |
External power, connector type | 2-pole jackable screw terminal |
Voltage | Allowed range 10-30 VDC |
Environmental data |
|
Operating temperature range | -15°C to +50°C |
Storage temperature range | -40°C to +70°C |
Humidity (operating and storage) | IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C |
EMC | - EN 61000-6-2:2001 (Immunity) - EN 61000-6-3:2001 (Emission) - FCC 47 CFR Part 15 Class B (Emission) |
Encapsulation | IP 40 (IEC 60529) |
Bump | 25g (IEC 60068-2-29) |
Vibration | 2g (IEC 60068-2-6) |
Physical data |
|
Weight | 0.7kg |
Camera size (L x W x H) | 170 x 70 x 70mm |
Tripod mounting | UNC1/4"-20 (on three sides) |
Base mounting | 2 x M4 thread mounting holes (on three sides) |
Housing materia | Aluminium |
The FLIR A310 camera offers an affordable and accurate temperature measurement solution for anyone who needs to solve problems that need built in "smartness" such as analysis, alarm functionality and autonomous communication using standard protocols. The FLIR A310 camera also has all the necessary features and functions to build distributed single- or multi-camera solutions utilizing standard Ethernet hardware and software protocols.
- Home
- |
- Products
- |
- Training
- |
- Application |
- Image Gallery |
- Contact Us
Copyright ©2012 - Thermoscan Co., Ltd. - All Rights Reserved.
Thermoscan Co., Ltd. (บริษัท เทอร์โมสแกน จำกัด)
731 PM Tower, 5th Floor, Asok Dindaeng Road, Dindaeng, Dindaeng, Bangkok 10400
Tel: (02) 642-9489 Fax: (02) 642-9424
E-mail: tms@thermoscan.co.th